
Emission Control Device
for DG Set
From expert installation to ongoing support, we deliver complete emission control services as a reliable retrofit emission control device provider. Our CPCB type-approved, ARAI-tested RECD systems are engineered for DG sets ranging from 15 kVA to 2500 kVA—ensuring compliance, performance, and cleaner power operations.
Zero Back Pressure
World's first & only RECD with zero back pressure as per ARAI test report
92.6% PM Reduction
Very high efficiency PM reduction along with 70%+ HC and CO reduction
20 Years Lifespan
Or 20,000 hours whichever is earlier - 3x longer than ESP systems
Self-Cleaning Tech
Continuous regeneration technology means negligible maintenance
Our RECD Services
Complete emission control solutions for diesel generators across Pan India
RECD Installation
Complete turnkey installation of CPCB Type-approved Retrofit Emission Control Device on your DG sets.
- Site survey & DG assessment
- Custom RECD sizing (15-2500 kVA)
- Professional installation in 48 hours
- Testing & commissioning
- ARAI tested certification
Annual Maintenance Contract
Comprehensive AMC for retrofitted emission control equipment for DG set to ensure peak performance and compliance.
- Quarterly inspections
- Self-cleaning technology support
- Performance monitoring
- Emergency breakdown support
- Combined RECD + DG maintenance
Compliance & Documentation
End-to-end support for CPCB, SPCB documentation and pollution board certifications.
- CPCB compliance documentation
- State PCB liaison support
- Certificate procurement
- Compliance audit assistance
- Renewal support
Technical Consultation
Expert guidance on emission control solutions from our experienced DG service team.
- Feasibility analysis
- Technology comparison (RECD vs ESP)
- Cost-benefit assessment
- ROI projections
- Customized solutions
Pan India Service Network
Nationwide service coverage ensuring quick response across all major industrial zones.
- Delhi NCR & North India
- Mumbai & Maharashtra
- South India coverage
- East & North East network
- Quick response team
Emission Testing & Reports
NABL-accredited emission testing services as per ISO 8178 5-mode D2 cycle standards.
- Pre-installation baseline testing
- Post-installation verification
- Periodic compliance monitoring
- Detailed emission reports
- ARAI standard testing
Our Service Installations Across India
Real RECD installations and maintenance work at various industrial facilities across Indian cities

Expert Installation

DG Set Integration

Healthcare Facility

Industrial Compliance

Technical Details

Service Team
RECD vs Electrostatic Precipitator
Why RECD is the superior choice for emission control
| Parameter | Our RECD | ESP |
|---|---|---|
| PM Capture Efficiency | Above 90% | Below 80% |
| Initial Cost | Low | Very High |
| Back Pressure | Zero (ARAI Tested) | High (More bends) |
| CO & HC Efficiency | More than 70% | 0% |
| Device Size | Compact (Silencer size) | Huge (50% of DG) |
| Installation Time | 1-3 days | 7-15 days |
| Operational Cost | Negligible | Moderate-High |
| Maintenance | Self-cleaning | Soot disposal challenge |
| Lifespan | 20 years / 20,000 hrs | 6 years / 6,000 hrs |
| Visible Smoke | No visible smoke | Heavy black smoke |
Installation Process
Quick 4-step process - Get your DG set compliant in just 1-3 days
Site Survey
Free assessment of your DG set and installation requirements
Custom Sizing
CFD simulated RECD design for your specific generator
Installation
Professional fitting - Horizontal, Vertical or Diagonal
Certification
Testing, commissioning and compliance documentation
Ready to Make Your DG Set Compliant?
Contact us today for a free consultation and site survey. Pan India service available.
retrofittedemissioncontroldevice.com